Title: Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm
Authors: Azizan As'arry; Khairil Anas Md Rezali; Nawal Aswan Abdul Jalil; Razali Samin; Zamir Aimaduddin Zulkefli; Mohd Zarhamdy Md. Zain
Addresses: Sound and Vibration Research Group, Department of Mechanical and Manufacturing Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia ' Sound and Vibration Research Group, Department of Mechanical and Manufacturing Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia ' Sound and Vibration Research Group, Department of Mechanical and Manufacturing Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia ' Sound and Vibration Research Group, Department of Mechanical and Manufacturing Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia ' Sound and Vibration Research Group, Department of Mechanical and Manufacturing Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia ' Department of Applied Mechanics and Design, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
Abstract: A person who has severe hand tremor will have difficulty in doing specific tasks such as eating, combing or holding any objects. Currently, there is no medication that can cure the tremor. Thus, this study proposes the active tremor control, in which an intelligent controller is applied to suppress the hand tremor. The main objective is to optimise the proportional-integral (PI) controller using genetic algorithm (GA). A linear voice coil actuator (LVCA) is applied onto a four degree of freedom (4-DOF) human hand model represented in state space. The findings of the study demonstrate that the PI controller optimised by GA gives excellent performance in reducing the tremor error. Based on the frequency evaluation, the PI controller performance was roughly around 84% in reducing the peak of simulated hand tremor. The outcomes provide an important contribution towards achieving novel methods in suppressing hand tremor model by means of intelligent control.
Keywords: human hand tremor; active tremor control; genetic algorithm.
DOI: 10.1504/IJAMECHS.2017.086207
International Journal of Advanced Mechatronic Systems, 2017 Vol.7 No.3, pp.151 - 157
Received: 08 Jun 2016
Accepted: 13 Jan 2017
Published online: 03 Sep 2017 *